Gc Fujicem Luting Glass Ionomer

In stock

  • Cartridge delivery always dispenses the correct ratios
  • Minimizes cement waste
  • Flexibility in the amount of cement that can be dispensed
  • Easier mixing in only 10 secs.
  • No air bubbles
  • Sufficient working time
  • Minimal film-thickness of only 3 µ.
  • Guaranteed adhesive strength
  • Effective fluoride release
  • Optimal clinical performance
Compare
Category: Tags: ,

Resin Reinforced Glass Ionomer Luting Cement

GC FujiCEM is the world’s first glass ionomer luting cement mixed from pastes. The specially developed Paste Pak System is designed to simplify dispensing and offer greater consistency in cementation helping to ensure a perfect result every time.

Indications:

  • Cementing all types of metal, porcelain fused to metal, and resin crowns, inlays, onlays and bridges
  • Cementing porcelain inlays
  • As a base or liner

Advantages

  • Cartridge delivery always dispenses the correct ratios
  • Minimizes cement waste
  • Flexibility in the amount of cement that can be dispensed
  • Easier mixing in only 10 secs.
  • No air bubbles
  • Sufficient working time
  • Minimal film-thickness of only 3 µ.
  • Guaranteed adhesive strength
  • Effective fluoride release
  • Optimal clinical performance

Key Specifications

COMPOSITION

PASTE A %by wt PASTE B % by wt
Aluminosilicate glass 60-70 distilled water 30-40
2-Hydroxyethyl methacrylate 10-20 polyacrylic acid 30-40
Urethane dimethacrylate 10-12
benzenosulfonic acid sodium salt
2-3
Silica powder 6 Silica Powder 2
Camphorquinone <1%
mixing time no. of crowns
10 sec single crown
15 sec 2-4 crowns
working time setting time
3 min 4min30sec

Note: Refridgeration of catridges extends the working time by 30 sec

CONTRAINDICATIONS

1. Pulp capping.

2. In rare cases the product may cause sensitivity in some people. If any such reactions are experienced, discontinue the use of the product and refer to a physician.

STORAGE

Store in a cool and dark place (4-25°C)(39.2-77.0°F). If not in use for a prolonged period of time, store in refrigerator.

Shelf life : 2 years from date of manufacture

Packaging

Gc Fujicem Refill Pack 13.3g Cartridge:

  • 1 Cartridge of 13.3 gm / 7.2 ml
  • Instruction Manual

Gc Fujicem Luting Glass Ionomer – Dispenser:

  • 1 x Dispenser only

Direction to Use

1. Paste Pak Cartridge Loading

a. Make sure that the piston is completely retracted into the dispenser.

Note : To retract the piston, hold both the slide block and release lever (on the underside of the dispenser) with fingers and pull them back together.

b. Load the cartridge into the Paste Pak Dispenser. 1) Ensure the mark on the cartridge lines up with the mark on the Paste Pak Dispenser as illustrated. 2) Then turn the cartridge fully to the right position. Note : To remove the cartridge, retract the piston fully and turn the cartridge back to the marked positions.

c. After cartridge loading, slide the release lever forward until it stops. a) Push the front of the release lever. b) Do not push the upper side.

2. Dispensing

a. Remove the cartridge cover.  b. Depress the lever to dispense the required amounts of paste onto the mixing pad.

Note : 1) Before dispensing the first material from a new cartridge or when dispensing after a long interval, bleed the pastes in order to prevent the incorporation of air bubbles into the material. 2) The finger grip can be moved forwards or backwards to change the quantity of material to be dispensed.

c. While depressing the lever, level and cut off the extruded material from the tips of the cartridge by moving the cartridge and dispenser to an upright position on the mixing pad. 1. Level and cut off material. 2. Depressing the lever. When the lever is released after dispensing, residual pastes at the tips are retracted into the cartridge. Replace the cartridge cover. Note : 1) If any surplus paste is retained on the cartridge tips after dispensing, remove with gauze, etc. 2) The amount of residual material in the cartridge can be confirmed by the position of the slide block on the underside of the dispenser. As the cartridge has translucent tips, the residual amount can also be confirmed by the position of the inner plunger seen through the tips. 3) Do not drop the dispenser with the cartridge. Otherwise the cartridge may be damaged.

3. Mixing

After dispensing, incorporate and spread the material out in a thin layer on the mixing pad using a plastic spatula. Mix thoroughly, with lapping strokes, for 10 seconds. Be careful not to incorporate air bubbles. Note : 1) The two pastes are similar in color, so mix with care. When a large amount is required for 2 – 4 crowns, mix for 15 seconds. 2) The working time is 3 minutes from the start of mixing at 23°C (73.4°F). Higher temperatures will shorten working time. 3) Do not mix GC FujiCEM pastes with other materials.

Be the first to review “Gc Fujicem Luting Glass Ionomer”

Your email address will not be published. Required fields are marked *

four + eighteen =

Reviews

There are no reviews yet.

Main Menu